2020年1月14日 星期二

AUTOCLAVED AERATED CONCRETE PANEL(AAC) ALC/AAC panel

AUTOCLAVED AERATED CONCRETE PANELAAC)Is the porous concrete, which composed of quartz sand, aluminum, lime, etc. as the main raw material, double-layer, two-way mesh reinforcement which is derusted and anticorrosion treatmented inside,Through high temperature, high pressure, steam curing etc.Is a new type of building materials with excellent performance at present.
1. Light weight: Bulk density 425~625kg/m³, Only for 1/4 concrete, 1/3 Clay brick, The weight of the building can be greatly reduced, and the design value is reduced too.
2. Fire resistance: 125mm AAC panel fire resistance can reach more than 4 hours, It is real fire prevention material in Grade A.50mm AAC panel can be met the fire protection requirements of steel structural members.
3. Anti crack: The shrinkage value of natural state is smaller than that of the clay brick, and the special technology is adopted to solve the problem of the quality of the slab cracks.
4. Thermal insulation: thermal insulation is only 0.11(B04), It is a new type of building material that can meet the building energy saving more than 65% by a single wall.
5. Seismic resistance: Allowable inter layer deflection angle 1/150, When the special node is used to achieve 1/120, In the case of all the nodes, the panel will not fall off when the 1/20 is changed in the layer;So that the anti-seismic effect is excellent.
6. Environmental protection: No radiation, Both the internal and external illumination coefficient are less than 0.1, is 1/4 of Fly ash board, Excellent sound insulation performance, 100mm AAC panel(Double sides putty)could reach 40.8dB, The sound insulation effect of is similar with 200mm fly ash brick wall.
7. Bearing capacity of Autoclaved Aerated Concrete Panel: The plates are equipped with internal double layers, two-way mesh reinforcement, can produce wall panels, partition wall, floor decking, roof board, decorative board etc..
8. economical: Using AAC board as the wall material, can effectively improve the use of the building area, reduce the use of energy consumption, to achieve the national building energy efficiency standards. Under the same sound insulation and fire protection requirements, AAC plate thickness is the smallest, and don't required the tie column, waist beam and other auxiliary components, This can reduce the wall load, thereby reducing the cost of construction.
9. Extensive: Can be used for concrete structure, steel structure residential buildings, office buildings, building internal and external wall body, floor slab, roof panel, firewall, explosion-proof wall, structural steel beams and columns fire maintenance, soundproof walls, old buildings and renovation.
10. Convenience: Eliminating the traditional building blocks in the process of the type of work, such as Mixing, masonry, plastering, reinforcement, formwork and concrete etc. Just the plate installation workers can do all the work, Avoid the conflict of work and mutual restraint.

Performance Indices in Grade B05
Item
Unit
Detection value
Test standard
Standard
value
Dry bulk density
kg/m³
512
GB/T11970-1997
±50
Cube compressive strength (average)
Mpa
≥4.0
GB/T11971-1997
≥2.5
Drying shrinkage
mm/m
0.48
GB/T11972-1997
≤0.8
Coefficient of thermal conductivity (water content 5%)
W/m.k
0.11
GB/T10295-2008
≤0.14
Frost
resistance
mass loss
%
1
GB/T11973-1997
≤5.0
Post freezing strength
Mpa
≥2.0
≥2.0
Impact resistance (30kg sand pendulum impact back without crack)
times
≥7.0
JC666-1997
3
The single point hanging force
N
1200(100mm AAC)
JC666-1997
≥800
1500(125mm AAC)
Bond strength between steel bar and AAC panel
Mpa
average value 2.4
GB/T15762-2008
≥1.0
Fire resistance limit of AAC plate
hour
100mm wall: 3.62
125mm wall: >4.0
GB/T9978-2008

Protective steel column fire resistance limit in 50mm AAC panel 
hour
>4.0
GB/T9978-2008
4
Protective steel beam fire resistance limit in 51mm AAC panel 
hour
>3.0
GB/T9978-2008
3
Water softening coefficient R/R
%
0.88
GB/T11970-1997

Average
sound
insulation
100mm AAC panel+Both sides putty
dB
41.8
GBJ75-84
GBJ121-88

125mm AAC panel+Both sides putty
45.1
150mm AAC panel+Both sides putty
46.6
175mm AAC panel+Both sides putty
48.1
200mm AAC panel+Both sides putty
51.3
Combination form-1(Both sides rock wool & AAC panel inside)150mm+40mm rock wool in both sides+10mm gypsum board(decoration)+Both sides putty
55.2
Combination form-2(Both sides AAC panel & rock wool inside)100mm AAC+50mm rock wool+100mm AAC
+Both sides putty
58.6
Dimension error
mm
L±3
W+0~2
T±1
GB/T15762-2008
L±4
W+0~4
T±2
Surface smoothness
mm
1
GB/T15762-2008
≤3
Linear expansion coefficient
/℃
7x10


Elastic modulus
N/mm
1.75x10


Permeability (6 days 300mm high water spout drop height)
mm
88.3
(Contrast test of standard red brick fell 283.3mm in 4 days)
refer to JISA5416-1997
≤100

Fire performance index of AAC inner wall plate
Wall thickness(mm)
50
75
100
125
150
Fire resistance time(hour)
1.57
>2
3.62
>4
>4

Specification of AAC inner wall plate
Thickness(mm)
75
100
125
≥150
Length(mm)
≤3000
≤4000
≤5000
≤6000

Specification of AAC external wall plate
                            Thickness
       Length max.        (mm)
                        (mm)
Design load
100
125
150
175
200
1.2KN/㎡
3600
4200
5200
6000
6000
1.4KN/㎡
3500
4200
4900
6000
6000
1.6KN/㎡
3300
4000
4700
5700
6000
1.8KN/㎡
3100
3900
4500
5400
6000
2.0KN/㎡
3000
3800
4300
5200
6000
2.2KN/㎡
2800
3600
4200
5000
5800
2.3KN/㎡
2700
3400
4100
4700
5600

Specification of AAC Roof plate
                            Thickness
       Length max.        (mm)
                        (mm)
Design load
100
125
150
175
200
1.4KN/㎡
2600
3100
3700
4600
5600
1.6KN/㎡
2500
2900
3600
4400
5400
1.8KN/㎡
2400
2700
3500
4200
5100
2.0KN/㎡
2300
2500
3300
4000
4800
2.2KN/㎡
2200
2300
3200
3800
4500
2.4KN/㎡
2100
2300
3100
3600
4200
2.6KN/㎡
2000
2300
3000
3400
3900

Thermal insulation performance of AAC external wall plate
Thickness
Thermal resistance
thermal inertia index
heat transfer resistance
heat transfer coefficient
δ(mm)
R(㎡.k/W)
D=∑RS
R0(㎡.k/W)
k(W/㎡.k)
50
0.31
0.92
0.46
2.17
75
0.45
1.31
0.60
1.67
100
0.59
1.69
0.74
1.35
125
0.72
2.07
0.87
1.15
150
0.86
2.45
1.01
0.99
175
1.00
2.83
1.15
0.87
200
1.14
3.22
1.29
0.78

Thermal insulation performance of AAC roof plate
Thickness
Thermal resistance
thermal inertia index
heat transfer resistance
heat transfer coefficient
δ(mm)
R(㎡.k/W)
D=∑RS
R0(㎡.k/W)
k(W/㎡.k)
150
0.81
2.28
0.96
1.04
175
0.93
3.20
1.08
0.93
200
1.05
3.59
1.20
0.83
225
1.17
3.97
1.32
0.76
250
1.29
4.36
1.44
0.69

ALC panel and AAC Panel are our main product. Our Autoclaved Aerated Concrete Panel can be used for concrete structure, steel structure residential buildings and office buildings. If you need, welcome to contact us to know more.


Our company supply kinds of sandwich panel, City Multifunctional Kiosk,ALC/AAC panel and custom steel structural . Our products have high quality and competitive prices.

For more product information, please click here.

沒有留言:

張貼留言